Parameterising 2/4xcounter module

4 × 16 bit counter (modes 8 ... 11)

12

Parameter setting via system bus (CAN) / CANopen

12.4

12.4.6

L

12.4−14

EDSPM−TXXX−9.0−11/2009

12.4.6

4 × 16 bit counter (modes 8 ... 11)

1

2

3

4

5

6

7

8

9

10

GND

+24 V DC

n.c.

In2 (CLK)

In3 (CLK)

n.c.

n.c.

In5 (CLK)

In6 (CLK)

n.c.

Counter 0.2

Counter 1.2

Counter 0.1

Counter 1.1

epm−t079

Fig. 12.4−20

Terminal assignment of the 2/4xcounter in the modes 8 ... 11

The modes 8 ... 11 offers four 16−bit counters which can be pre−assigned with a
starting value.

The modules differ in having different counting directions:

Mode 8:

l

Counters 0.2 and 1.2 count up

l

Counters 0.1 and 1.1 count up

Mode 9:

l

Counters 0.2 and 1.2 count down

l

Counters 0.1 and 1.1 count up

Mode 10:

l

Counters 0.2 and 1.2 count up

l

Counters 0.1 and 1.1 count down

Mode 11:

l

Counters 0.2 and 1.2 count down

l

Counters 0.1 and 1.1 count down

Each LOW−HIGH edge at input IN2 / IN3 / IN5 / IN6 (CLK) causes the associated
counter to count up and / or down, respectively.