Transmitting parameter data
Addressing with slot and index
Networking via PROFIBUS−DP
10.5
10.5.3
L
10.5−5
EDSPM−TXXX−9.0−11/2009
The following PROFIBUS Gateway elements can be accessed via slot number 0:
Slot number
Index
Access
Description
0
A0
h
R
Read out device name (PROFIBUS Gateway or PROFIBUS GatewayECO)
A1
h
R
Read out hardware version
A2
h
R
Read out software version
A3
h
R
Read out serial number (e.g. 000347 = 30
h
, 30
h
, 30
h
, 33
h
, 34
h
, 37
h
)
A4
h
R
Read out device configuration
(see table "Device configuration")
D0
h
R
Read out number of saved diagnostics
W
Delete diagnostic input
D1
h
R
Read out stored diagnostic input
(see table "Structure of a saved diagnostic input")
W
Save diagnostic input in FLASH−ROM
R = read
W = write
Device configuration
The electronic modules belonging to PROFIBUS Gateway can be output via index
A4
h
:
Electronic module
Identification
Input data
Output data
[Byte]
[Byte]
8×digital input
9FC1h
1
−
16×digital input
9FC2h
2
−
8×digital output 1A
AFC8h
−
1
16×digital output 1A
AFD0
h
−
2
8×digital output 2A
AFC8h
−
1
4×relay
AFC8h
−
1
8×digital input / output
BFC9h
1
1
4×analog input
15C4h
8
−
4×analog input ±10V
15C4h
8
−
4×analog input ±20mA
15C4h
8
−
4×analog output
25E0
h
−
8
4×analog output ±10V
25E0
h
−
8
4×analog output 0...20mA
25E0
h
−
8
4×analog input / output
45DBh
4
4
2/4×counter
B5F4h
10
10
SSI interface
B5DBh
4
4
1×counter/16×digital input
08C0h
6
6
Structure of saved diagnostic entry
Every time index D1
h
is accessed, a saved diagnostic entry is read out. When it is
accessed for the first time, the last entry is read out, when it is accessed the second
time, the penultimate entry is read out, etc.
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
...
Byte 26
Length of diagnostic
data
Internal time stamp
Diagnostic data
(maximum 20 bytes)
Data of PROFIBUS Gateway