13 parameter setting via profibus−dp – Lenze EPM−T9XX Modular system User Manual

Page 488

Advertising
background image

Parameterising 2/4xcounter module

Encoder with GATE (modes 36 ... 38)

13

Parameter setting via PROFIBUS−DP

13.2

13.2.19

L

13.2−54

EDSPM−TXXX−9.0−11/2009

The counter is incremented by 1 on

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

l

a HIGH−LOW edge (track A) at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

epm−t168

Fig. 13.2−75

Signal characteristic of 2/4xcounter in the mode 37 (upcounter)

The counter is decremented by 1 on

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

l

a HIGH−LOW edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

epm−t169

Fig. 13.2−76

Signal characteristic of 2/4xcounter in the mode 37 (downcounter)

Signal characteristic in mode 37