Appendix, Index table – Lenze EPM−T9XX Modular system User Manual

Page 524

Advertising
background image

Index table

15

Appendix

15.1

L

15.1−10

EDSPM−TXXX−9.0−11/2009

Index

Important

Possible settings

Name

Selection

Lenze

I2360

h

*

Property function
forcing

0

0

{1}

1

·

Forcing of digital outputs (I6200

h

) and

analog outputs (I6411

h

)

·

After a restart, I2360

h

is set 0

0

Forcing deactive in "Pre−Operational" state

Forcing only possible in "Operational" state

1

Forcing active in "Pre−Operational" state

Forcing only possible in "Pre−Operational"
state

I2361

h

CAN mode

0

0

{1}

1 Display only

Active communication mode

0

Lenze system bus mode

1

CANopenmode

I2400

h

¿

Timer value

0

{1 ms}

65535 Monitoring time for process data input

objects
For the compact system, only index I2400

h

,

subindex 1 is available

^ 8.9−1

1 PD01

0

2 PD02

0

3 PD03

0

4 PD04

0

5 PD05

0

6 PD06

0

7 PD07

0

8 PD08

0

9 PD09

0

10 PD10

0

I2410

h

*

Time−out short
circuit monitoring

2

0

{1 ms}

65535 Only available for the compact system.

If a digital output has a short circuit and
the time set has been exceeded, the
module switches to the status set in
I1029

h

, subindex 2.

I2500

h

Dummy object for
PDO mapping

Display only
Index is only available in the compact
system

I3001

h

¿

Config
analog/counter
module 1

00000000

h

{1

h

}

FFFFFFFF

h

Configuration of analog module,
2/4xcounter module, SSI interface module
or 1xcounter/16xdigital input module on
slot 1

·

I3001

h

can only be accessed via Global

Drive Control (GDC). Use I3401

h

in

CoDeSys programming systems.

·

I3001

h

is only available for the modular

system.

^ 12.3−1

^ 12.4−1

^ 12.5−1

^ 12.6−1

1

0

h

2

0

h

3

0

h

4

0

h

I3002

h

¿

Config
analog/counter
module 2

00000000

h

{1

h

}

FFFFFFFF

h

Configuration of analog module,
2/4xcounter module, SSI interface module
or 1xcounter/16xdigital input module on
slot 2

·

I3002

h

can only be accessed via Global

Drive Control (GDC). Use I3401

h

in

CoDeSys programming systems.

·

I3002

h

is only available for the modular

system.

^ 12.3−1

^ 12.4−1

^ 12.5−1

^ 12.6−1

1

0

h

2

0

h

3

0

h

4

0

h

I3003

h

¿

Config
analog/counter
module 3

00000000

h

{1

h

}

FFFFFFFF

h

Configuration of analog module,
2/4xcounter module, SSI interface module
or 1xcounter/16xdigital input module on
slot 3

·

I3003

h

can only be accessed via Global

Drive Control (GDC). Use I3401

h

in

CoDeSys programming systems.

·

I3003

h

is only available for the modular

system.

^ 12.3−1

^ 12.4−1

^ 12.5−1

^ 12.6−1

1

0

h

2

0

h

3

0

h

4

0

h