5 parameterising ssi interface, 1 parameter data, Parameterising ssi interface – Lenze EPM−T9XX Modular system User Manual

Page 377: Parameter data, Parameterising ssi interface parameter data

Advertising
background image

Parameterising SSI interface

Parameter data

12

Parameter setting via system bus (CAN) / CANopen

12.5

12.5.1

L

12.5−1

EDSPM−TXXX−9.0−11/2009

12.5

Parameterising SSI interface

12.5.1

Parameter data

Use index I4104

h

to define the process data mapping (PDO mapping) for the

input/output bytes and the control byte of the SSI interface:

l

I4104

h

= 0: SSI mapping PLC

– PDO mapping is required for data evaluation with PLC units using the

function blocks "L_IOSSIDataToIO" and "L_IOSSIDataFromIO".

l

I4104

h

= 1: SSI mapping standard 1 and

I4104

h

= 2: SSI mapping standard 2

– PDO mapping is required for data evaluation with 9300 controllers using

the function blocks "CAN−IN" and "CAN−OUT".

)

Note!

"SSI mapping standard 1" and "SSI mapping standard 2" differ in
the arrangement of the input/output bytes and the control byte.

l

Please read the documentation for the controller, in particular
for the CAN−IN function block, to see which mapping is to be
used for communication.

For the SSI interface, 4 bytes of parameter data are available, which are assigned
via SDOs. The following can be defined via the parameter data:

l

Baud rate

l

Coding type

l

Evaluation of the combined I/O.0

Parameter setting via Global Drive Control (GDC):

Depending on the plug−in station, the SSI interface is parameterised via the indices
I3001

h

... I3010

h

(max. 8 SSI interface modules). The parameter data are stored in

subindex 1.

Parameter setting via CoDeSys:

The max. 8 SSI interface modules are addressed via index I3401

h

. The parameter

data are assigned in the subindices 1 ... 64 (4 bytes per subindex). The SSI
interface module assigns 1 subindex.

Index

Subindex

1

00

00

h

h

00

00

h

h

Byte 1

Byte 3

Byte 0

Byte 2

I3xxx

h

epm−t173

Fig. 12.5−1

Display of the parameter data of the SSI interface

Mapping setting

Baud rate, code and hold
function setting

Advertising