Transmitting parameter data

Addressing with slot and index

10

Networking via PROFIBUS−DP

10.5

10.5.3

L

10.5−3

EDSPM−TXXX−9.0−11/2009

10.5.3

Addressing with slot and index

)

Note!

Prerequisite for addressing data via slot and index:

l

Master and slave have to support the communication protocol
PROFIBUS−DP−V1.
– The connection can be established via a class 1 master

(DPM 1) or class 2 masters (DPM 2).

l

The function blocks SFB 52 (read) and SFB 53 (write) must be
integrated in the slaves PROFIBUS Gateway and PROFIBUS
GatewayECO.
– For further information, refer to the documentation on SFB 52

and SFB 53 (Siemens).

PROFIBUS interprets a slave as a logic entity with a physical modular structure.

Module

PROFIBUS

Gateway

8×digital

output 1A

16×digital

output 1A

8×digital

input

4×analog

input

...

Slot number

0

1

2

3

4

...

Index

0 ... 255

0 ... 255

0 ... 255

0 ... 255

0 ... 255

...

Request

...

1 byte

(slot number 1)

2 bytes

(slot number 2)

...

Response

...

1 byte

(slot number 3)

8 bytes

(slot number 4)

...

Fig. 10.5−3

Example of slave configuration