background image

Parameterising analog modules

Signal functions of 4xanalog input /output

12

Parameter setting via system bus (CAN) / CANopen

12.3

12.3.11

L

12.3−19

EDSPM−TXXX−9.0−11/2009

Paramete
r bytes
2/3

Tolerance

2)

Format

1)

Signal range

Signal function

7D

h

Voltage
measurement

0 ... 10 V

0.00
0

{0.01V}

{1

dec

}

+10.00

+27648

S7

Two’s

complement

±0.4 %

Min.

Limit

values

Max.

0.00
0

+11.76 V

+32511

dec

3A

h

Current
measurement

±20 mA

−20.00
−16384

{0.01 mA}

{1

dec

}

+20.00

+16384

S5

Two’s

complement

±0.3 %

Min.

Limit

values

Max.

−25.00 mA
−20480

dec

+25.00 mA

+20480

dec

76

h

Current
measurement

0 ... 20
mA

0.00
0

{0.01 mA}

{1

dec

}

+20.00

+16384

S5

Two’s

complement

±0.6 %

Min.

Limit

values

Max.

0.00
0

+25.00 mA

+20480

dec

2C

h

Current
measurement

±20 mA

−20.00
−27648

{0.01 mA}

{1

dec

}

+20.00

+27648

S7

Two’s

complement

±0.3 %

Min.

Limit

values

Max.

−23.51 mA
−32512

dec

+23.51 mA

+32511

dec

2D

h

Current
measurement

4 ... 20
mA

+4.00
0

{0.01 mA}

{1

dec

}

+20.00

+27648

S7

Two’s

complement

±0.8 %

Min.

Limit

values

Max.

+1.18 mA
−4864

dec

+22.81 mA

+32511

dec

7E

h

Current
measurement

0 ... 20
mA

0.00
0

{0.01 mA}

{1

dec

}

+20.00

+27648

S7

Two’s

complement

±0.6 %

Min.

Limit

values

Max.

0.00
0

+23.52 mA

+32511

dec

FF

h

Analog input deactivated

1)

Format of the input data (

12.3−7).

2)

Tolerance of the input range at an ambient temperature of 25 °C. Sensor inaccuracies were not considered.

Lenze setting of the signal function in parameter bytes 2 and 3: 3B

h

Advertising