Appendix, Index table – Lenze EPM−T9XX Modular system User Manual

Page 522

Advertising
background image

Index table

15

Appendix

15.1

L

15.1−8

EDSPM−TXXX−9.0−11/2009

Index

Important

Possible settings

Name

Selection

Lenze

I1806

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

TxPDO 7

960

385

{1}

2047 Defining the individual identifiers for

process data object 7

2 Transmission type

255

0

{1}

255 Defining the transmission mode

0

Function deactivated

The output data are accepted on sync
telegram transmission.

1 ... 240

Process data transfer after sync no. 1
...
Process data transfer after sync no. 240

The output data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.

254

Time−controlled process data transfer

Only if a cycle time is set in I180x

h

,

subindex 5

255

Event−controlled process data transfer

255

Event−controlled process data transfer with cyclic
overlay

Only if a cycle time is set in I180x

h

,

subindex 5

3 Inhibit time

0

0

{1 ms}

65535 Inhibit time

5 Event time

0

0

{1 ms}

65535 Cycle time

I1807

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

TxPDO 8

1216

385

{1}

2047 Defining the individual identifiers for

process data object 8

2 Transmission type

255

0

{1}

255 Defining the transmission mode

0

Function deactivated

The output data are accepted on sync
telegram transmission.

1 ... 240

Process data transfer after sync no. 1
...
Process data transfer after sync no. 240

The output data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.

254

Time−controlled process data transfer

Only if a cycle time is set in I180x

h

,

subindex 5

255

Event−controlled process data transfer

255

Event−controlled process data transfer with cyclic
overlay

Only if a cycle time is set in I180x

h

,

subindex 5

3 Inhibit time

0

0

{1 ms}

65535 Inhibit time

5 Event time

0

0

{1 ms}

65535 Cycle time

I1808

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

TxPDO 9

1728

385

{1}

2047 Defining the individual identifiers for

process data object 9

2 Transmission type

255

0

{1}

255 Defining the transmission mode

0

Function deactivated

The output data are accepted on sync
telegram transmission.

1 ... 240

Process data transfer after sync no. 1
...
Process data transfer after sync no. 240

The output data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.

254

Time−controlled process data transfer

Only if a cycle time is set in I180x

h

,

subindex 5

255

Event−controlled process data transfer

255

Event−controlled process data transfer with cyclic
overlay

Only if a cycle time is set in I180x

h

,

subindex 5

3 Inhibit time

0

0

{1 ms}

65535 Inhibit time

5 Event time

0

0

{1 ms}

65535 Cycle time

Advertising