Parameterising 2/4xcounter module

Measuring the pulse width, fref programmable (mode 20)

13

Parameter setting via PROFIBUS−DP

13.2

13.2.11

L

13.2−28

EDSPM−TXXX−9.0−11/2009

13.2.11

Measuring the pulse width, f

ref

programmable (mode 20)

1

2

3

4

5

6

7

8

9

10

GND

+24 V DC

In1 (RES)

In2 (PULSE)

In3 (DIR)

Out0

In4 (RES)

In5 (PULSE)

In6 (DIR)

Out1

Counter

0

Counter

1

epm−t075

Fig. 13.2−35

Terminal assignment of the 2/4xcounter in the mode 20

The pulse widths of the signal at the input IN2 / IN5 (PULSE) are measured with a
programmable time base (f

ref

, see figure Counter access").

The measuring process starts with a HIGH−LOW edge at input IN2 / IN5 (PULSE)
and ends with the LOW−HIGH edge.

A LOW−HIGH edge of the measured signal stores the pulse width with the unit
1/f

ref

. This result can be found and read out in the data output range until the next

result appears.

The counting direction is determined via the signal level at input IN3 / IN6 (DIR).

Upcounter: LOW level
Downcounter: HIGH level

During the counting process, a LOW level must be applied to input IN1 / IN4 (RES).
A HIGH level deletes the counter.

Output OUT0 / OUT1 has no function.

Terminal assignment

PULSE signal

DIR signal

RES signal

OUT signal