Network via canopen – Lenze EPM−T9XX Modular system User Manual

Page 225

Advertising
background image

Transmitting process data

Compatibility with Lenze drive and automation components

9

Network via CANopen

9.3

9.3.7

L

9.3−9

EDSPM−TXXX−9.0−11/2009

9.3.7

Compatibility with Lenze drive and automation components

The tables below will assist you in finding out at which stage a modular system or
which compact module, respectively, can be operated in combination with a Lenze
drive and automation component.

Compatibility is dependent on the available process data objects (PDO).

Process data objects (PDO) of the I/O system IP20 (slave)

Module type

Module requires

PDO−Rx

PDO−Tx

Modular system

8×digital input

1/8

16×digital input

2/8

8×digital output 1A

1/8

8×digital output 2A

1/8

16×digital output 1A

2/8

8×digital input / output

1/8

1/8

4×relay

1/8

4×analog input

8/8

4×analog output

8/8

4×analog input / output

8/8

8/8

2/4×counter

8/8 + 2/8

8/8 + 1/8

SSI interface

8/8

8/8

1×counter/16×digital input

8/8

8/8

Compact system

8×dig. I/O compact

8/8

8/8

16×dig. I/O compact

8/8

8/8

16×dig. I/O compact (single−wire conductor)

8/8

8/8

16×dig. I/O compact (three−wire conductor)

8/8

8/8

Process data objects (PDO) of the Lenze drive and automation components (master)

Components

PDO−Rx [x

PDO−Rx

]

PDO−Tx [x

PDO−Tx

]

9300 Servo PLC

>10

>10

Drive PLC
9300 inverter (all standard types)

2

2

8200 vector frequency inverter
8200 motec frequency inverter
Communication module EMF2175

)

Note!

l

A modular system allows the connection of max. 32 modules in
addition to the CAN gateway.

l

A modular system offers max. 20 PDOs (10 PDO−Rx and
10 PDO−Tx) for process data exchange.

l

Since 9300 Servo PLC and Drive PLC are able to manage more
than 20 process data objects, several modular systems can be
operated on a Servo PLC or Drive PLC. For this each CAN
gateway must be assigned to a unique node address.

A control task requires the connection of 4 digital outputs, 10 digital inputs and
3 analog outputs to an 8200 vector frequency inverter.

Example