Parameterising 2/4xcounter module

Encoder (modes 1, 3, and 5)

13

Parameter setting via PROFIBUS−DP

13.2

13.2.4

L

13.2−9

EDSPM−TXXX−9.0−11/2009

The counter is incremented by 1 on

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

l

a HIGH−LOW edge (track A) at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

RES

B

A

Counter

00000001

00000000

XXXX

00000002

00000003

00000004

00000005

00000006

00000007

00000008

00000009

TreH2d

TcIH2d

TcIH

TdL2cIH

TcIH2dH

TcIL

epm−t071

Fig. 13.2−10

Signal characteristic of 2/4xcounter in the mode 3 (upcounter)

The counter is decremented by 1 on

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

l

a HIGH−LOW edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

RES

B

A

Counter

FFFFFFFF

00000000

FFFFFFFE FFFFFFFD FFFFFFFC FFFFFFFB FFFFFFFA FFFFFFF9 FFFFFFF8 FFFFFFF7

XXXXX

TreH2d

TdL2cIH

TcIH

TcIH2d

TcIL

TcIH2dH

epm−t072

Fig. 13.2−11

Signal characteristic of 2/4xcounter in the mode 3 (downcounter)

Signal characteristic in mode 3