Parameterising 2/4xcounter module

Encoder with GATE (modes 36 ... 38)

12

Parameter setting via system bus (CAN) / CANopen

12.4

12.4.19

L

12.4−54

EDSPM−TXXX−9.0−11/2009

epm−t165

Fig. 12.4−74

Counter access of the 2/4xcounter in the modes 36, 37 and 38

Every HIGH−LOW edge at input IN2 / IN5 (A) increments the counter by 1 if a HIGH
level is applied to input IN3 / IN6 (B) at this time.

epm−t166

Fig. 12.4−75

Signal characteristic of 2/4xcounter in the mode 36 (upcounter)

Every LOW−HIGH edge at input IN2 / IN5 (A) decrements the counter by 1 if a HIGH
level is applied to input IN3 / IN6 (B) at this time.

epm−t167

Fig. 12.4−76

Signal characteristic of 2/4xcounter in the mode 36 (downcounter)

Counter access