13 parameter setting via profibus−dp – Lenze EPM−T9XX Modular system User Manual

Page 456

Advertising
background image

Parameterising 2/4xcounter module

Measuring the frequency (modes 16 and 18)

13

Parameter setting via PROFIBUS−DP

13.2

13.2.9

L

13.2−22

EDSPM−TXXX−9.0−11/2009

Mode 16:

The output OUT 0 is set to HIGH level when the

measuring process starts, and is

set to LOW level, when the

measuring process is completed. The output OUT1

indicates the output signal of OUT0 in an inverted way.

Mode 18:

The output OUT 0 is set to HIGH level when the

counting process starts, and is set

to LOW level, when the

counting process is completed. The output OUT1 indicates

the output signal of OUT0 in an inverted way.

f

+

f

ref

@ m

n

f

Frequency to be computed

f

ref

Reference frequency (see figure "counter access")

m

Content, counter 1 (number of CLK pulses)

n

Number of reference frequency pulses in counter 0 (corresponds to Compare
unless prematurely terminated by a HIGH signal at input IN4 (STOP)

)

Note!

If the reference frequency [f

ref

] and the number of reference

frequency pulses [n] are selected so that the wanted frequency [f]
is exactly 1 Hz, the counter 1 directly displays this frequency.
Example: m = 1,000,000; f

ref

= 1 MHz.

OUT signal

Computing the frequency