The modular system, 4×relay – Lenze EPM−T9XX Modular system User Manual

Page 63

Advertising
background image

4×relay

4

The modular system

4.12

L

4.12−3

EDSPM−TXXX−9.0−11/2009

Maximum relay contact switching capacity

Relay contact life

20 30

50

100

200 300

U [V]

0.2

0.5

2

3

4

5

1

0.3

0.4



‚

I [A]

100

50

30

20

10

0.5

1

2

3 4 5

10

100

n

ƒ

„

…

epm−t018

epm−t019

Fig. 4.12−3

Diagrams for the module 4×relay

I

Contact current

n

Number of switching cycles × 10

4

U

Contact voltage

ƒ Service life at AC 125 V

 Switching capacity at AC voltage

„ Service life at DC 30 V

‚ Switching capacity at DC voltage

… Service life at AC 230 V

Type

4×relay

Voltage supply

DC 5 V / 150 mA (via backplane bus)

Connectable cable cross−section

£ 2.5 mm

2

(

³ AWG 14)

Relay outputs

Number

4

Max. contact voltage

AC 230 V
DC 30 V

Max. contact current

5A

Max. relay switching frequency

100 Hz

Communication

Output data

1 byte (bit 0 ... bit 3)

Dimensions

Width

25.4 mm

Height

76.0 mm

Depth

76.0 mm

Weight

80 g

Order designation

EPM−T222

Technical data

Advertising