Lenze EPM−T9XX Modular system User Manual

Page 364

Advertising
background image

Parameterising 2/4xcounter module

Encoder with G/RES (modes 28 ... 30)

12

Parameter setting via system bus (CAN) / CANopen

12.4

12.4.15

L

12.4−44

EDSPM−TXXX−9.0−11/2009

The counter is incremented by 1 on

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

l

a HIGH−LOW edge at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

l

a HIGH−LOW edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

epm−t152

Fig. 12.4−61

Signal characteristic of 2/4xcounter in the mode 30 (upcounter)

The counter is decremented by 1 on

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

l

a HIGH−LOW edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

l

a LOW−HIGH edge at input IN2 / IN5 (A) and a LOW level at the input
IN3 / IN6 (B).

l

a HIGH−LOW edge at input IN2 / IN5 (A) and a HIGH level at input
IN3 / IN6 (B).

epm−t153

Fig. 12.4−62

Signal characteristic of 2/4xcounter in the mode 30 (downcounter)

Signal characteristic in mode 30

Advertising