1 general data/operating conditions, General data/operating conditions, Technical data – Lenze EPM−T9XX Modular system User Manual

Page 27

Advertising
background image

General data/operating conditions

3

Technical data

3.1

L

3.1−1

EDSPM−TXXX−9.0−11/2009

3.1

General data/operating conditions

)

Note!

l

The technical data of the modules of the modular system is
included in the chapter "The modular system" in the
corresponding module description.

l

The technical data of the modules of the compact system is
included in the chapter "The compact system" in the
corresponding module description.

Conformity and approval
Conformity

CE

73/23/EEC

Low−Voltage Directive

Approval

UL

UL 508

Power Conversion Equipment

Protection of persons and device protection
Type of protection

IP20

Electrical isolation

Modular system, compact modules

To the fieldbus

Via optocouplers

To the process level

Via optocouplers

Insulation resistance

IEC 61131−2

Insulation voltage to reference earth

Inputs / outputs

AC/DC 50 V, test voltage AC 500 V

Protective measures

Against short circuit

EMC
Noise emission

EN 61000−6−4

Noise immunity

EN 61000−4−2

ESD

EN 61000−4−3

HF interference (enclosure)

EN 61000−4−4

Burst

Ambient conditions
Climatic

Storage

IEC/EN 60068−2−14

−25 ... +70 °C

Operation

Horizontal installation EN 61131−2

0 ... +60 °C

Vertical installation

0 ... +40 °C

Air humidity

60068−2−30

RH1 (without condensation, relative humidity 10 ... 95 %)

Pollution

EN EN 61131−2

Degree of pollution 2

Mechanical

Vibration resistance

IEC 60068−2−6

1 g

IEC 60068−2−27

15 g

Mounting conditions
Mounting place

In the control cabinet

Mounting position

Horizontal and vertical

Station design

Modular system

1 gateway module with up to 32 electronic modules attached to it
without any free space

General data

Operating conditions

Advertising