Parameterising SSI interface

Parameter data

13

Parameter setting via PROFIBUS−DP

13.3

13.3.1

L

13.3−1

EDSPM−TXXX−9.0−11/2009

13.3

Parameterising SSI interface

13.3.1

Parameter data

l

For the SSI interface, 4 bytes of parameter data are available. The following
are defined via the parameter data

– Baud rate

– Coding type

– Evaluation of the combined I/O.0

l

The module can be parameterised with the configuration tool or via slot and
index.

– To set the parameters via slot and index, the function blocks SFB 52 (read)

and SFB 53 (write) are required.

(

10.5−3)

Slot number

Index

Access

Description

1 ... 32

00

h

R

Read out diagnostic data record 0

W

Write parameters to the module

01

h

R

The corresponding diagnostic data record of the electronic module can be
read out via the index.

·

Example:

– Index 01

h

: read out diagnostic data record 1

– Index 02

h

: read out diagnostic data record 2

F1

h

R

Read out the module parameters

F2

h

R

Read out the process image of the module

R = read

W = write