Diagnostics

Diagnostic data

10

Networking via PROFIBUS−DP

10.6

10.6.2

L

10.6−5

EDSPM−TXXX−9.0−11/2009

Byte

Assignment

Byte 1

Bit 5 ... 0

Module from which the diagnostic data is transmitted.
000000

Module on slot 1

000001

Module on slot 2

...

...

000111

Module on slot 8

Bit 7, 6

10

Fix, code for channel−related diagnostics

Byte 2

Bit 5 ... 0

Channel of localised module
000000

Channel 1

000001

Channel 2

...

...

111111

Channel 63

Byte 2

Bit 7, 6

Type of localised module
00

Input module

01

Output module

11

Input/output module

Byte 3

Bit 4 ... 0

Error according to PROFIBUS standard
00001

Short circuit

00010

Supply voltage too low

00011

Supply voltage too high

00100

Module output overloaded

00101

Overtemperature at the output module

00110

Cable break of the connected sensor or actuator

00111

Maximum limit value exceeded

01000

Minimum limit value exceeded

01001

Incorrect load voltage at the output

– Encoder supply
– Hardware error of the module

Manufacturer−specific error
10000

Parameter setting error

10001

No encoder or load voltage

10010

Defective fuse

10100

Mass error

10101

Reference channel error

10110

Process alarm lost

11001

Safety−oriented disconnection

11010

External error

11010

Error cannot be specified

Bit 7 ... 5

Channel type
001

1 Bit

010

2 bits

011

4 Bit

100

8 bits (1 byte)

101

16 bits (1 word)

110

32 bits (1 double word)