CAN gateway

4

The modular system

4.1

L

4.1−4

EDSPM−TXXX−9.0−11/2009

Type

CAN gateway

Voltage supply

Voltage

DC 24 V (DC 20.4 ... 28.8 V)

Max. current consumption CAN Gateway

0.7 A

Max. current consumption of electronic
modules

3,5 A

Connectable cable cross−section

£ 2.5 mm

2

(

³ AWG 14)

Communication

Communication protocol

·

System bus (CAN)

·

CANopen (CAL−based communication profile DS301/DS401)

Communication medium

DIN ISO 11898

Network topology

Line (terminated at both ends)

Max. cable length

Baud rate [kbit/s]

10

20

50

100

125

250

500

800

1000

Cable length [m]

5000 2500 1000

600

500

250

80

50

25

Max. number of nodes

63

Electrical isolation from system bus

Yes, via optocouplers

Connectable electronic modules

Max. number of elements

32

Max. number of digital input/output
modules

32

Max. number of analog input/output
modules

9

Max. number 2/4×counters

4

Max. number SSI interface

9

Max. number of 1×counter/16×digital
input

9

Max. digital input data

72 bytes

Max. digital output data

72 bytes

Max. analog input data

72 bytes

Max. analog output data

72 bytes

Dimensions

Width

25.4 mm

Height

76.0 mm

Depth

76.0 mm

Weight

80 g

Order designation

EPM−T110