Subindex 1 ) – Lenze EPM−T9XX Modular system User Manual

Page 381

Advertising
background image

Parameterising SSI interface

Input data assignment via index

12

Parameter setting via system bus (CAN) / CANopen

12.5

12.5.2

L

12.5−5

EDSPM−TXXX−9.0−11/2009

l

The output data of the modules (subindex 1 ... 9) are indicated under index
I4100

h

:

Index

I4100

h

Subindex 1

00

00

00

h

h

h

Byte 0

Byte 1

Byte 2

Byte 3

Bit

Bit

Bit

0

0

0

1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7

epm_t209

Fig. 12.5−6

Mapping of the output data under I4100

h

, subindex 1 (module 1)

Byte

Assignment

0

Reserved

1

SSI encoder value (LOW byte)

Bits 0 ... 7

Output of SSI encoder value

2

SSI encoder value (MID byte)

Bits 0 ... 7

3

SSI encoder value (HIGH byte)

Bits 0 ... 7

l

The status of the switching conditions for module I/O.0 and I/O.1 is
indicated under index I4102

h

(subindex 1 ... 9):

Index

I4102

h

Subindex 1

00

h

Byte 0

Bit

0

1

2

3

4

5

6

7

epm_t206

Fig. 12.5−7

Mapping of the status byte under I4102

h

, subindex 1 (module 1)

Byte

Assignment

0

Status

Bit 0

Status I/O.0

Bit 1

Status I/O.1

Bits 2 ... 7

Reserved

Advertising