Appendix, Index table – Lenze EPM−T9XX Modular system User Manual

Page 518

Advertising
background image

Index table

15

Appendix

15.1

L

15.1−4

EDSPM−TXXX−9.0−11/2009

Index

Important

Possible settings

Name

Selection

Lenze

I1402

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

RxPDO 3

512

385

{1}

2047 Defining the individual identifiers for

process data object 3

2 Transmisson type

255

0

{1}

255 Defining the transmission mode

0 ... 240

Process data update on sync telegram
transmission

The input data are accepted on sync
telegram transmission.

241
... 254

Reserved

255

Process data update on occurrence of an event

Every received value is accepted

I1403

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

RxPDO 4

830

385

{1}

2047 Defining the individual identifiers for

process data object 4

2 Transmisson type

255

0

{1}

255 Defining the transmission mode

0 ... 240

Process data update on sync telegram
transmission

The input data are accepted on sync
telegram transmission.

241
... 254

Reserved

255

Process data update on occurrence of an event

Every received value is accepted

I1404

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

RxPDO 5

1024

385

{1}

2047 Defining the individual identifiers for

process data object 5

2 Transmisson type

255

0

{1}

255 Defining the transmission mode

0 ... 240

Process data update on sync telegram
transmission

The input data are accepted on sync
telegram transmission.

241
... 254

Reserved

255

Process data update on occurrence of an event

Every received value is accepted

I1405

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

RxPDO 6

1080

385

{1}

2047 Defining the individual identifiers for

process data object 6

2 Transmisson type

255

0

{1}

255 Defining the transmission mode

0 ... 240

Process data update on sync telegram
transmission

The input data are accepted on sync
telegram transmission.

241
... 254

Reserved

255

Process data update on occurrence of an event

Every received value is accepted

I1406

h

¿

Index is only available in the modular
system

^ 8.3−3

1 COB−ID used by

RxPDO 7

1152

385

{1}

2047 Defining the individual identifiers for

process data object 7

2 Transmisson type

255

0

{1}

255 Defining the transmission mode

0 ... 240

Process data update on sync telegram
transmission

The input data are accepted on sync
telegram transmission.

241
... 254

Reserved

255

Process data update on occurrence of an event

Every received value is accepted

Advertising