Parameterising 2/4xcounter module

Encoder (modes 1, 3, and 5)

12

Parameter setting via system bus (CAN) / CANopen

12.4

12.4.4

L

12.4−9

EDSPM−TXXX−9.0−11/2009

epm−t141

Fig. 12.4−9

Counter access of the 2/4xcounter in the modes 1, 3 and 5

Every HIGH−LOW edge at input IN2 / IN5 (A) increments the counter by 1 if a HIGH
level is applied to input IN3 / IN6 (B) at this time.

RES

B

A

Counter

0000 0000

XXXX

0000 0001

0000 0002

0000 0003

0000 0004

0000 0005

0000 0006

TreH2d

TcIH2d

TcIH

TdL2cIH

TcIH2dH

TcIL

epm−t069

Fig. 12.4−10

Signal characteristic of 2/4xcounter in the mode 1 (upcounter)

Every LOW−HIGH edge at input IN2 / IN5 (A) decrements the counter by 1 if a HIGH
level is applied to input IN3 / IN6 (B) at this time.

RES

B

A

Counter

0000 0000

XXXX

FFFF FFFF

FFFF FFFE

FFFF FFFD

FFFF FFFC

FFFF FFFB

FFFF FFFA

TreH2d

TdL2cIH

Tt0H

TcIH2d

Tt0L

TcIH2dH

epm−t068

Fig. 12.4−11

Signal characteristic of 2/4xcounter in the mode 1 (downcounter)

Counter access

Signal characteristic in mode 1