Transmitting parameter data

PROFIBUS−DP−V0

10

Networking via PROFIBUS−DP

10.5

10.5.1

L

10.5−1

EDSPM−TXXX−9.0−11/2009

10.5

Transmitting parameter data

10.5.1

PROFIBUS−DP−V0

DU

(1 Byte)

DU

(1 Byte)

DU

(1 Byte)

Header

SD

Checksum

ED

epm−t230

Fig. 10.5−1

Cycle of a PROFIBUS telegram

DU

Data Unit (user data)

Value range: 1 ... 244 bytes

SD

Start Delimiter (start of the telegram)

ED

End Delimiter (end of the telegram)

For the communication protocol PROFIBUS−DP−V0, the following parameter data
are available:

Byte

Assignment

Lenze setting

0

Bit 7 ... 0

Reserved

00

h

1

Bit 7 ... 0

Reserved

00

h

2

Bit 7 ... 0

Reserved

08

h

3

Bit 7 ... 0

Reserved

0A

h

4

Bit 7 ... 0

Reserved

81

h

5

Bit 7 ... 0

Reserved

00

h

6

Bit 7 ... 0

Reserved

00

h

7

Bit 0

0

Code−related diagnostics activated

70

h

1

Code−related diagnostics deactivated

Bit 1

0

Module status enabled

1

Module status inhibited

Bit 2

0

Channel−related diagnostics activated

1

Channel−related diagnostics deactivated

Bit 3

Reserved

Bit4

0

Manufacturer−specific alarm deactivated

1

Manufacturer−specific alarm activated

Bit 5

0

Diagnostic alarm deactivated

1

Diagnostic alarm activated

Bit 6

0

Process alarm deactivated

1

Process alarm activated

Bit7

Reserved

8

Bit 7 ... 0

Reserved

00

h

9

Bit 7 ... 0

Reserved

00

h

10

Bit 7 ... 0

Reserved

00

h

11

Bit 7 ... 0

Reserved

00

h

12

Bit 7 ... 0

Reserved

00

h