Lenze EPM−T9XX Modular system User Manual

Page 379

Advertising
background image

Parameterising SSI interface

Input data assignment via index

12

Parameter setting via system bus (CAN) / CANopen

12.5

12.5.2

L

12.5−3

EDSPM−TXXX−9.0−11/2009

l

The input data of the modules (subindex 1 ... 8) are set under index I4101

h

:

Index

I4101

h

Subindex 1

00

00

00

00

h

h

h

h

Byte 0

Byte 1

Byte 2

Byte 3

Bit

Bit

Bit

Bit

0

0

0

0

1

1

1

1

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

7

epm_t207

Fig. 12.5−2

Mapping of the input data under I4101

h

, subindex 1 (module 1)

Byte

Assignment

0

Control

Bits 0 ... 1

Setpoint selection
00: No setpoint selection
01: Setpoint selection for output I/O.0
10: Setpoint selection for output I/O.1
11: Setpoint selection for outputs I/O.0 and I/O.1

Bit 2

Reserved

Bit 3

Condition for setting the output = HIGH
0: If SSI encoder value > setpoint
1: If SSI encoder value < setpoint

Bits 4 ... 7

Reserved

1

Comparison value (LOW byte)

Bits 0 ... 7

Selection of comparison value

2

Comparison value (MID byte)

Bits 0 ... 7

3

Comparison value (HIGH byte)

Bits 0 ... 7

l

The output data of the modules (subindex 1 ... 8) are indicated under index
I4100

h

:

Index

I4100

h

Subindex 1

00

00

00

00

h

h

h

h

Byte 0

Byte 1

Byte 2

Byte 3

Bit

Bit

Bit

Bit

0

0

0

0

1

1

1

1

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

7

epm_t208

Fig. 12.5−3

Mapping of the output data under I4100

h

, subindex 1 (module 1)

Byte

Assignment

0

Status

Bit 0

Status I/O.0

Bit 1

Status I/O.1

Bits 2 ... 7

Reserved

1

SSI encoder value (LOW byte)

Bits 0 ... 7

Output of SSI encoder value

2

SSI encoder value (MID byte)

Bits 0 ... 7

3

SSI encoder value (HIGH byte)

Bits 0 ... 7

I4104

h

= 0 (SSI mapping PLC)