1 servopack ratings and specifications, 1 single-phase/three-phase 200 v, 2 three-phase 400 v – Yaskawa SGDH Linear Sigma Series User Manual

Page 100: 1 servopack ratings and specifications -2, Caution

Advertising
background image

4 SERVOPACK Specifications and Dimensional Drawings

4.1.1 Single-phase/Three-phase 200 V

4-2

4.1 SERVOPACK Ratings and Specifications

4.1.1 Single-phase/Three-phase 200 V

The value of the input power supply voltage is maximum 253 Vrms.

4.1.2 Three-phase 400 V

The value of the input power supply voltage is maximum 528 Vrms.

• Take appropriate measures to ensure that the input power supply is supplied within the specified voltage

range.
An incorrect input power supply may result in damage to the SERVOPACK. If the voltage exceeds these values, use
a step-down transformer so that the voltage will be within the specified range.

CAUTION

SERVOPACK
Model SGDH-

A5A 01A 02A 04A 05A 08A 10A 15A 20A 30A 50A

75A

Max. Applicable
Servomotor
Capacity (kW)

0.05

0.1

0.2

0.4

0.45 0.75

1.0

1.5

2.0

3.0

5.0

7.5

Continuous Out-
put Current
(Arms)

0.64 0.91

2.1

2.8

3.8

5.7

7.6

11.6 18.5 24.8 32.9

54.7

Max. Output Cur-
rent (Arms)

2.0

2.8

6.5

8.5

11.0 13.9

17

28

42

56

84

130

Input
Power
Supply

Main
Circuit

Single-phase/Three-phase 200 to 230 VAC

+10 to -15%, 50/60 Hz

Control
Circuit

Single-phase 200 to 230 VAC

+10 to -15%, 50/60 Hz

Configuration

Base-mounted (Rack mounting available as an option)

Base-mounted (Duct-
ventilated available as
an option)

Regenerative
Processing

External regenerative
resistor

Built-in

External regenerative
resistor

SERVOPACK Model SGDH-

05D

10D

15D

20D

30D

50D

75D

Max. Applicable Servomotor
Capacity (kW)

0.45

1.0

1.5

2.0

3.0

5.0

7.5

Continuous Output Current
(Arms)

1.9

3.5

5.4

8.4

11.9

16.5

25.4

Max. Output Current (Arms)

5.5

8.5

14

20

28

40.5

65

Input Power
Supply

Main Circuit

Three-phase 380 to 480 VAC

+10 to -15%, 50/60 Hz

Control Circuit

24 VDC

±15%

Configuration

Base-mounted
(Rack mounting available as an option)

Base-mounted (Duct-venti-
lated available as an option)

Regenerative Processing

Built-in

External regenerative resistor