9 switching gain settings, 9 switching gain settings -25, 3) related parameters – Yaskawa SGDH Linear Sigma Series User Manual

Page 347

Advertising
background image

10.4 Servo Gain Adjustment Functions

10-25

10

10.4.9 Switching Gain Settings

Gain switching by the external signal is possible with the SGDH SERVOPACK. For example, to use different
gains while the servomotor is running or stopped, set two values in the gain settings 1 and 2 and switch the gains
by the external signal.

(1) Gain Switching Input Signal

(2) Switchable Gain Combinations

Turning ON and OFF the gain switching signal /G-SEL switches the gains as follows.

(3) Related Parameters

Type

Signal

Connector Pin No.

Setting

Meaning

Input

/G-SEL

Signal allocation

required

OFF: H (high)
level

Gain settings 1

ON: L (low) level Gain settings 2

To use the input signal, the input terminal must be allocated in the parameter Pn50D. Refer to 8.3.2 Input Circuit Signal
Allocation
.

Gain Switching Signal (/G-SEL)

OFF (H Level)

ON (L Level)

Speed loop gain

Pn100

Pn104

Speed loop integral time constant

Pn101

Pn105

Position loop gain

Pn102

Pn106

Parameter

Function

Pn50A

n.†††1

Enables the input signal allocation for the sequence.

Set to allocate the gain switching signal (/G-SEL) to an input terminal.

Pn100

Speed Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 2,000

Hz

40

Immediately

Pn101

Speed Loop Integral Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

15 to 51,200

(0.15 to 512.00 ms)

0.01 ms

2,000

(20.00 ms)

Immediately

Pn102

Position Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 2,000

1/s

40

Immediately

Pn104

2nd Speed Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 2,000

Hz

40

Immediately

Pn105

2nd Speed Loop Integral Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

15 to 51,200

(0.15 to 512.00 ms)

0.01 ms

2,000

(20.00 ms)

Immediately

Pn106

2nd Position Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 2,000

1/s

40

Immediately

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Advertising