7 Wiring
7.5.2 Wiring for Noise Control
7-34
(3) Using Noise Filters
Use an inhibit type noise filter to prevent noise from the power supply line. The following table lists recom-
mended noise filters for each SERVOPACK model.
Install a noise filter on the power supply line for peripheral equipment as necessary.
Precautions when using noise filter
Always observe the following installation and wiring instructions. Incorrect use of a noise filter halves its
benefits.
1. Do not put the input and output lines in the same duct or bundle them together.
Voltage
SERVOPACK Model
Recommended Noise Filters
Model
Specifications
Manufacturer
Single-phase
200 V
SGDH-A5AE to -02AE
FN2070-6/07
Single-phase 250 VAC, 6A
SCHAFFNER
SGDH-04AE
FN2070-10/07
Single-phase 250 VAC, 10A
Three-phase
200 V
SGDH-05AE
FN258L-7/07
Three-phase 480 VAC, 7A
SGDH-08AE to -20AE
FN258L-16/07
Three-phase 480 VAC, 16A
SGDH-30AE
FN258L-30/07
Three-phase 480 VAC, 30A
SGDH-50AE
FMAC-0934-5010 Three-phase 440 VAC, 50A
SCHURTER
(formely
TIMONTA)
SGDH-75AE
FMAC-0953-6410 Three-phase 440 VAC, 64A
Three-phase
400 V
SGDH-05DE to -15DE
FN258L-7/07
Three-phase 480 VAC, 7A
SCHAFFNER
SGDH-20DE, -30DE
FN258L-16/07
Three-phase 480 VAC, 16A
SGDH-50DE, -75DE
FS5559-35-33
Three-phase 480 VAC, 35A
IMPORTANT
Noise
filter
Incorrect
Correct
Separate these circuits
Box
Box
Box
Box
Noise
filter
Noise
filter
Noise
filter