12.4 List of Parameters

12-27

12

* 1. The setting range for the software version 32 or later
* 2. Available only for the software version 32 or later

Parameter

No.

Name

Setting Range

Unit

Factory

Setting

Setting

Validation

Reference

Section

Pn100

Speed Loop Gain

1 to 2000

1 Hz

40

Immedi-

ately

10.3.4

Pn101

Speed Loop Integral Time Constant

15 to 51200

0.01 ms

2000

Immedi-

ately

10.3.5

Pn102

Position Loop Gain

1 to 2000

1/s

40

Immedi-

ately

10.3.3

Pn103

Mass Ratio

0 to 10000

(0 to 20000)

∗1

1%

0

Immedi-

ately

9.2.2
9.2.3

10.2.6

Pn104

2nd Speed Loop Gain

1 to 2000

1 Hz

40

Immedi-

ately

10.4.9

Pn105

2nd Speed Loop Integral Time Constant

15 to 51200

0.01 ms

20.00

Immedi-

ately

10.4.9

Pn106

2nd Position Loop Gain

1 to 2000

1/s

40

Immedi-

ately

10.4.9

Pn108

Bias Width Addition

0 to 250

1 reference

unit

7

Immedi-

ately

10.4.6

Pn109

Feed-forward

0 to 100

1%

0

Immedi-

ately

10.4.1

Pn10A

Feed-forward Filter Time Constant

0 to 6400

0.01 ms

0

Immedi-

ately

10.4.1

Pn10B

Gain-related Application Switches

0000

After

restart /

Immedi-

ately

Pn10C

Mode Switch Force Reference

0 to 800

1%

200

Immedi-

ately

10.4.5

0

1

2

3

4

0

1

0

1

2

3

Use internal force reference as the condition. (Level setting: Pn10C)

Use speed reference as the condition. (Level setting: Pn181)

Use acceleration as the condition. (Level setting: Pn182)

Use position error pulse as the condition. (Level setting: Pn10F)

No mode switch function available

PI control

I-P control

No automatic gain switching available

Position reference

Position error

Both position reference and position error

Mode Switch Selection

(Refer to 10.4.5 Using the Mode Switch (P/PI Switching.))

Setting

Validation

Setting

Validation

Speed Loop Control Method

(Refer to 10.3.5 Speed Loop Integral Time Constant.

Reserved (Do not change)

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

Immediately

After restart

After restart

Automatic Gain Switching Selection

(Refer to 10.4.11)

∗2

Setting

Validation

∗2