5 Specifications and Dimensional Drawings of Serial Converter Unit

5-2

5.1 Serial Converter Unit Specifications

(1) Model: JZDP-D00†-†††

(2) Characteristics and Specifications

* 1. The current consumption of the linear scale and hall sensor is not included in this value.

The current consumption of linear scale and hall sensor must be taken into consideration for the cur-
rent capacity of host controller that supplies the power. The current consumption of hall sensor:
Approx. 40 mA.

* 2. Input a value within the specified range. Otherwise, incorrect position information is output, and the

device may be damaged.

* 3. The transmission is enabled 100 to 300 ms after the power turns ON.

Items

Specifications

Electrical
Characteristics

Power Supply Voltage

+5.0V

±5%, ripple content 5% max.

Current Consumption

∗1

120 mA Typ. 350 mA Max.

Signal Resolution

Input 2-phase sine wave: 1/256 pitch

Max. Response
Frequency

250 kHz

Analog Input Signals

∗2

(cos, sin, Ref)

Differential input amplitude: 0.4 V to 1.2V
Input signal level: 1.5 V to 3.5V

Hall Sensor Input
Signal

CMOS level

Output Signals

∗3

Position data, hall sensor information, and alarms

Output Method

Serial data transmission
(HDLC (High-level Data Link Control) protocol format
with Manchester codes)

Transmission Cycle

62.5

μs

Output Circuit

Balanced transceiver (SN75LBC176 or the equivalent)
Internal terminal resistance: 120

Ω

Mechanical
Characteristics

Approx. mass

150 g

Vibration Resistance

98 m/s

2

max. (1 to 2500 Hz) in three directions

Shock Resistance

980 m/s

2

, (11 ms) two times in three directions

Environmental
Conditions

Operating temperature

0

°C to 55 °C (32 to 131 °F)

Storage temperature

-20

°C to +80 °C (-4 to +176 °F)

Humidity

20 % to 90 %RH (without condensation)