8 Digital Operator/Panel Operator

8.4.5 Allowable Maximum Motor Speed for Dividing Ratio Monitor (For the software version 32 or later)

8-34

8.4.5 Allowable Maximum Motor Speed for Dividing Ratio Monitor (For the software

version 32 or later)

This section describes the monitor display for determining the maximum speed (Pn384) for the PG Divider
(Pn281). Adjust the setting of Pn080.3 to select the location to be monitored. This function is available for Ser-
vopack Software version 32 or later.

Step

Display after

Operation

Digital Operator

Panel Operator

Description

1

Press the DSPL/SET or MODE/SET Key to select the mon-
itor mode.

2

Press the UP or DOWN Key to select “Un010.”

3

Press the DATA/ENTER Key once or DATA/SHIFT Key
for more than one second to display the motor maximum
speed that can be set.

4

Press the DSPL/SET or MODE/SET Key to display the
maximum dividing ratio that can be set.

5

Press the DATA/ENTER Key once or DATA/SHIFT Key
for more than one second to return to the display of monitor
number.