12.4 List of Parameters

12-33

12

Parameter

No.

Name

Setting Range

Unit

Factory

Setting

Setting

Validation

Reference

Section

Pn50A

Input Signal Selection 1

2100

After

restart

0

1

2

3

4

5

6

7

8

9

A

B

0

1

ON when CN1-40 input signal is ON (L-level)

ON when CN1-41 input signal is ON (L-level)

ON when CN1-42 input signal is ON (L-level)

ON when CN1-43 input signal is ON (L-level)

ON when CN1-44 input signal is ON (L-level)

ON when CN1-45 input signal is ON (L-level)

ON when CN1-46 input signal is ON (L-level)

Sets signal ON.

Sets signal OFF.

OFF when CN1-40 input signal is OFF (H-level)

OFF when CN1-41 input signal is OFF (H-level)

OFF when CN1-42 input signal is OFF (H-level)

/S-ON Signal Mapping

Signal Polarity: Normal: Servo ON when ON (L-level)

Signal Polarity: Reverse: Servo ON when OFF (H-level)

(Refer to 9.6.1 Setting the Servo ON Signal.)

0 to F Same as /S-ON

/P-CON Signal Mapping (P control when ON (L-level))

Refer to 10.4.4 Proportional Control Operation (Proportional Operation Reference).)

4th

digit

3rd

digit

2nd

digit

1st
digit

n.

OFF when CN1-43 input signal is OFF (H-level)

OFF when CN1-44 input signal is OFF (H-level)

OFF when CN1-45 input signal is OFF (H-level)

OFF when CN1-46 input signal is OFF (H-level)

C

D

E

F

0

1

2

3

4

5

6

7

8

9

A

B

Forward run allowed when CN1-40 input signal is ON (L-level)

Forward run allowed when CN1-41 input signal is ON (L-level)

Forward run allowed when CN1-42 input signal is ON (L-level)

Forward run allowed when CN1-43 input signal is ON (L-level)

Forward run allowed when CN1-44 input signal is ON (L-level)

Forward run allowed when CN1-45 input signal is ON (L-level)

Forward run allowed when CN1-46 input signal is ON (L-level)

Forward run prohibited

Forward run allowed

Forward run allowed when CN1-40 input signal is OFF (H-level)

Forward run allowed when CN1-41 input signal is OFF (H-level)

Forward run allowed when CN1-42 input signal is OFF (H-level)

Forward run allowed when CN1-43 input signal is OFF (H-level)

Forward run allowed when CN1-44 input signal is OFF (H-level)

Forward run allowed when CN1-45 input signal is OFF (H-level)

Forward run allowed when CN1-46 input signal is OFF (H-level)

C

D

E

F

Uses the sequence input signal terminals with standard allocation.

Changes the sequence input signal allocation for each signal.

Input Signal Allocation Mode

(Refer to 8.3.2 Input Circuit Signal Allocation.)

P-OT Signal Mapping (Forward run prohibited when OFF (H-level))

Refer to 9.6.3 Setting the Overtravel Limit Function.)