2.3
Σ-II Series SERVOPACKs and Applicable Linear Servomotors
2-5
2
Note: The model combinations shown in this table are used when the maximum rated force of the appli-
cable linear servomotor is required. To suppress rises in temperature, larger linear servomotors are
used in some cases. If so, the SERVOPACK capacity can be lowered if using a motor at a lower
force than the rated force. Calculate the required current and select a model with a margin of
approximately 20%. An allowance can be made for up to 1/3 of the combined capacity of the linear
servomotor and SERVOPACK in the table.
SGLTW
(With T-type iron core)
22 models
20A170A
−
05AE
−
20A320A
−
10AE
−
20A460A
−
15AE
−
35A170A
−
08AE
−
35A320A
−
15AE
−
35A460A
−
20AE
−
35A170H
−
08AE
−
35A320H
−
15AE
−
50A170H
−
08AE
−
50A320H
−
15AE
−
40A400B
−
20AE
−
40A600B
−
50AE
−
80A400B
−
50AE
−
80A600B
−
75AE
−
35D170H
−
−
10DE
35D320H
−
−
20DE
50D170H
−
−
10DE
50D320H
−
−
20DE
40D400B
−
−
30DE
40D600B
−
−
50DE
80D400B
−
−
50DE
80D600B
−
−
75DE
Linear
Σ Series Linear Servomotor
Σ-II Series SGDH SERVOPACK
Single-phase
200 VAC
Three-phase
200 VAC
Three-phase
400 VAC