background image

12 Appendix

12.4.2 List of Parameters

12-28

* 1. Pn111 will be effective when Pn110.1 is set “0.”
* 2. Available for the software version 32 or later

Parameter

No.

Name

Setting Range

Unit

Factory

Setting

Setting

Validation

Reference

Section

Pn10F

Mode Switch Position Error Pulse

0 to 10000

1 reference

unit

0

Immedi-

ately

10.4.5

Pn110

Online Autotuning Switches

0010

After

restart

Pn111

Speed Feedback Compensation

*1

1 to 500

1%

100

Immedi-

ately

10.4.8

Pn124

Automatic Gain Switching Timer

∗2

1 to 10000

1 ms

100

Immedi-

ately

Pn125

Automatic Gain Switching Width

∗2

1 to 250

1 reference

unit

7

Immedi-

ately

Pn180

Bias

0 to 450

1 mm/s

0

Immedi-

ately

10.4.6

Pn181

Mode Switch Speed Reference

0 to 5000

1 mm/s

0

Immedi-

ately

10.4.5

Pn182

Mode Switch Acceleration

0 to 30000

1 mm/s

2

0

Immedi-

ately

10.4.5

0

1

Uses speed feedback compensation.

Does not use speed feedback compensation. (Standard speed feedback)

Speed Feedback Compensation Selection

(Refer to 10.4.8 Speed Feedback Compensation.)

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

Reserved (Do not change)

0

1

2

Tunes only at the beginning of operation.

Always tunes.

Does not perform autotuning.

Online Autotuning Selection

0

1

2

Disabled

Friction compensation: Small

Friction compensation: Large

Friction Compensation Selection

Advertising