7 Wiring

7.5.3 Using More Than One SERVOPACK

7-36

7.5.3 Using More Than One SERVOPACK

The following diagram is an example of the wiring when more than one SERVOPACK is used.
Connect the alarm output (ALM) terminals for the three SERVOPACKs in series to enable alarm detection relay
1RY to operate.
When the alarm occurs, the ALM output signal transistor is turned OFF.
Multiple servos can share a single molded-case circuit breaker (QF) or noise filter. Always select a QF or noise
filter that has enough capacity for the total power capacity (load conditions) of those servos. For details, refer to
2.6.2 Molded-case Circuit Breaker and Fuse Capacity.

R S

T

QF

1KM

1KM

1RY

SUP

1KM

1RY

+24V

L1
L2
L3

L1C

CN1

31 ALM+

32 ALM-

0V

M

L2C

M

M

Power supply

Noise
filter

Power
ON

Power
OFF

SERVOPACK

Linear servomotor

Linear servomotor

Linear servomotor

Note: Wire the system so that the phase-S power supply will be the ground phase.

L1
L2
L3

L1C

CN1

31 ALM+

32 ALM -

L2C

SERVOPACK

L1
L2
L3

L1C

CN1

31 ALM+

32 ALM -

L2C

SERVOPACK