(2) Reference Pulse Input Signal Timing

The reference pulse input signal timing is shown below.

Table 9.1 Reference Pulse Input Signal Timing

Reference Pulse Signal Form

Electrical Specifications

Remarks

Sign and pulse train input
(SIGN and PULS signal)
Maximum reference frequency:
500 kpps
(For open-collector output: 200 kpps)

t1,t2

0.1 ms

t3,t7

0.1 ms

t4,t5,t6 > 3

μs

τ

1.0

μs

(

τ

/T)

× 100

50%

Sign (SIGN)
H = Forward
reference
L = Reverse
reference

CW pulse and CCW pulse
Maximum reference frequency:
500 kpps
(For open-collector output: 200 kpps)

t1,t2

0.1

μs

t3 > 3

μs

τ

1.0

μs

(

τ

/T)

× 100

50%

Two-phase pulse train with 90

°

phase differential (phase A and
phase B)
Maximum reference frequency
×1 input pulse multiplier: 500 kpps
×2 input pulse multiplier: 400 kpps
×4 input pulse multiplier: 200 kpps

t1,t2

0.1

μs

τ

1.0

μs

(

τ

/T)

× 100 = 50%

Switching of
the input pulse
multiplier
mode is done
with parameter
Pn200.0 set-
ting.

Forward
reference

Reverse
reference

t1 t2

t3

t4

t5

t6

t7

T

τ

SIGN

PULS

Forward
reference

Reverse
reference

t2

t3

T

τ

CW

CCW

t1

Phase B leads
phase A by 90

°

Phase B lags
phase A by 90

°

Forward reference

Reverse reference

Phase B

Phase A

t2

τ

T

t1