2 input signal settings, 3 operating using an internally set speed – Yaskawa SGDH Linear Sigma Series User Manual

Page 310

Advertising
background image

9 Operation

9.10.2 Input Signal Settings

9-66

9.10.2 Input Signal Settings

The following input signals are used to switch the operating speed.

9.10.3 Operating Using an Internally Set Speed

Use ON/OFF combinations of the following input signals to operate with the internally set speeds.

Note: Signal OFF = High level; Signal ON = Low level

„

Control Mode Switching

When Pn000.1 = 4, 5, or 6, and either /P-CL (/SPD-A) or /N-CL (SPD-B) is OFF (high level), the control
mode will switch.
Example:
When Pn000.1=5: Internally set speed selection

Position control (pulse train)

Type

Signal

Name

Connector Pin

Number

Meaning

Input

/P-CON

CN1-41

Switches the linear servomotor movement direction.

(/SPD-D)

Must be allocated

Input

/P-CL

CN1-45 Selects

the internally set speed.

(/SPD-A)

Must be allocated

Input

/N-CL

CN1-46

Selects the internally set speed.

(/SPD-B)

Must be allocated

„ Input Signal Selection

The following two types of operation can be performed using the internally set speeds:

• Operation with the /P-CON, /P-CL, and /N-CL input signals (pins allocated in factory setting)
• Operation with the /SPD-D, /SPD-A, and /SPD-B input signals

/SPD-D, /SPD-A, and /SPD-B input signals must be allocated with parameter Pn50C. Refer to 8.3.2 Input Circuit Signal
Allocation

.

Input Signal

Motor

Movement

Direction

Speed

/P-CON

(/SPD-D)

/P-CL

(/SPD-A)

/N-CL

(/SPD-B)

OFF (high)

OFF (high) OFF (high)

Forward

Stop at 0 of the internally set speed

OFF (high)

ON (low)

Pn380: Internally Set Speed 1 (SPEED1)

ON (low)

ON (low)

Pn381: Internally Set Speed 2 (SPEED2)

ON (low)

OFF (high)

Pn382: Internally Set Speed 3 (SPEED3)

ON (low)

OFF (high) OFF (high)

Reverse

Stop at 0 of the internally set speed

OFF (high)

ON (low)

Pn380: Internally Set Speed 1 (SPEED1)

ON (low)

ON (low)

Pn381: Internally Set Speed 2 (SPEED2)

ON (low)

OFF (high)

Pn382: Internally Set Speed 3 (SPEED3)

Input Signal

Speed

/P-CL (/SPD-A)

/N-CL (/SPD-B)

OFF (high)

OFF (high)

Pulse train reference input (position control)

OFF (high)

ON (low)

Pn380: Internally Set Speed 1 (SPEED1)

ON (low)

ON (low)

Pn381: Internally Set Speed 2 (SPEED2)

ON (low)

OFF (high)

Pn382: Internally Set Speed 3 (SPEED3)

IMPORTANT

Advertising