11 Inspection, Maintenance, and Troubleshooting

11.1.4 Warning Display Table when the Application Module is Used

11-6

11.1.4 Warning Display Table when the Application Module is Used

The following special warnings will occur when the SGDH SERVOPACK and an application module are used
together. The relation between warning displays and warning code outputs is shown in Table 11.4.

Note: 1. The following types of application modules are available:

NS100 (JUSP-NS100): MECHATROLINK-I application module
NS115 (JUSP-NS115): MECHATROLINK-II application module
NS300 (JUSP-NS300): DeviceNet application module
NS500 (JUSP-NS500): PROFIBUS-DP application module
NS600 (JUSP-NS600): INDEXER application module

2. For troubleshooting application module alarms, refer to relevant application module manual.

Manual numbers are described in Related Manuals on page v.

3. When mounting the NS115 module, observe the following restrictions on use. If the hand-held

digital operator is connected or the communications are being sent or from SigmaWin+ and
another device (a personal computer), the following MECHATROLINK-II commands can not
be carried out unconditionally (command warning: A.95) and the commands are not successfully
sent.

PRM_RD, PRM_WR, PPRM_WR, CONFIG, ALM_RD, ALM_CLR,
SENS_ON, ADJ, ID_RD

Table 11.4 Warning Displays and Outputs when the SERVOPACK and an Application Module Is Used Together

Warning

Display

Application Module

which Detects

Warnings

Warning Name

Meaning

Warning Code

Output

Servo
Alarm

(ALM)

Output

NS

100

NS

115

NS

300

NS

500

NS

600

ALO1 ALO2 ALO3

A.94

{

{

{

{

Data Setting Warning

A value outside the setting range
was set using communications.

L

L

H

L

A.95

{

{

{

{

Command Warning

A command not supported in the
product specifications was issued.
The command reception condi-
tions were not met.

H

L

H

L

A.96

{

{

{

Communications
Warning

A communications error occurred
(once).

L

H

H

L

A.98

{

{

Main Power OFF

The main power supply is not
being supplied.

L

L

L

L

A.9A

{

{

Not Completed within
the Set Time

Positioning was not completed
within the set time.

L

H

L

L

A.9F

{

NS600 Error

Some error occurred in the NS600.
Check the NS600 Error Display
for details.

L

L

L

L

Advertising