5 linear scales, 5 linear scales -14 – Yaskawa SGDH Linear Sigma Series User Manual

Page 48

Advertising
background image

2 Selections

2.6.5 Linear Scales

2-14

2.6.5 Linear Scales

Note: 1. The linear scale signal is multiplied by eight bits (256 segmentation) inside the serial converter

unit.

2. Using the zero-point signal with a linear scale made by Renishaw Inc. may cause a deviation in

the home position. If so, adjust the setting so that the zero-point is output only in one direction
by using BID/DIR signal.

3. This list does not cover all the applicable types of linear scales. And, the linear scales listed in

the table may not be applicable or available if their specifications have been modified or their
production has been stopped.
Check the most recent catalog of the linear scale manufacturer to select a linear scale that meets
the specifications described in 5.1 Serial Converter Unit Specifications.

4. Select a linear scale so that the current consumption of the linear scale is 190 mA max.
5. At parameter (Pn280), set the scale pitch of the linear scale so that it satisfies the following con-

dition. Otherwise, satisfactory control cannot be obtained.

Manufacturer

Type

Output Signal

Resolution
(

μm/pulse)

Scale Pitch

(

μm)

Max. Value

of Encoder

Output

Resolution

(Pn281)

Max. Speed of

Applicable Linear

Servomotor

(m/s)

Renishaw Inc.

RGH22B

1Vpp
Analog voltage

0.078

20

31

5

63

4

127

2

255

1

Heidenhain
Corp.

LIDA187

0.156

40

63

5

127

4

255

2

LIDA487
LIDA489

0.078

20

31

5

63

4

127

2

255

1

LIF181

0.016

4

31

1.0

63

0.8

127

0.4

255

0.2

64000

must result in an integer number

Pn280(Scale pitch (

μm))

Examples
Correct: 1,2,4,8,10,16,20,40
Incorrect: 3,12,18

Advertising