5 external regenerative resistor, 5 external regenerative resistor -21, Refer to 6.8.5 external regenerative resistor – Yaskawa SGDH Linear Sigma Series User Manual

Page 149

Advertising
background image

6.8 Peripheral Devices

6-21

6

6.8.5 External Regenerative Resistor

Regenerative resistors for SERVOPACKs are internally or externally mounted as shown in the table below.
Regenerative resistors can be externally mounted on all SERVOPACKs. Connect an external regenerative resis-
tor to the SERVOPACK if regenerative energy exceeds the capacity of the SERVOPACK.
If a regenerative resistor is to be mounted externally, the jumper between B2 and B3 for the internal regenerative
resistor must be removed. Refer to 7.6 Connecting Regenerative Resistors for the selection.
No built-in regenerative resistor is provided to 7.5 kW SERVOPACKs. Be sure to prepare the externally
mounted regenerative resistor.
The following table shows examples of regenerative resistors.

* 1. The values in parentheses are for the optional JUSP-RA05 regenerative resistor.
* 2. The values in parentheses are for the optional JUSP-RA18 regenerative resistor.

The external regenerative resistor must be purchased by customers. Refer to the table below for selecting an
external regenerative resistor. Refer to 7.6 Connecting Regenerative Resistors for the connection.

Applicable SERVOPACK

Specifications for a Regenerative

Resistor Mounted in a

SERVOPACK

Min. Allowable

Resistance

(

Ω)

Resistance (

Ω)

Capacity (W)

Single-phase 200 V

SGDH-A5AE

40

SGDH-01AE
SGDH-02AE
SGDH-04AE

Three-phase 200 V

SGDH-05AE

50

60

40

SGDH-08AE
SGDH-10AE
SGDH-15AE

30

70

20

SGDH-20AE

25

140

12

SGDH-30AE

12.5

140

12

SGDH-50AE

8

280

8

SGDH-75AE

(3.13)

∗1

(1760)

∗1

2.9

Three-phase 400 V

SGDH-05DE

108

70

73

SGDH-10DE
SGDH-15DE
SGDH-20DE

45

140

44

SGDH-30DE
SGDH-50DE

32

180

28

SGDH-75DE

(18)

∗2

(880)

∗2

14.2

Advertising