12.3 Connection to Host Controller

12-17

12

12.3.2 Example of Connection to OMRON’s Motion Control Unit

*

represents twisted-pair wires.

Note: 1. Only signals applicable to OMRON’s MC unit and Yaskawa’s SGDH SERVOPACK are shown

in the diagram.

2. The main circuit power supply is a three-phase 200 VAC SERVOPACK input in the example.

The power supply and wiring must be in accordance with the power supply specifications of the
SERVOPACK to be used.

3. Note that incorrect signal connection will cause damage to the MC unit and SERVOPACK.
4. Open the signal lines not to be used.
5. The above connection diagram shows only X-axis connection. When using another axes, make

connection to the SERVOPACK in the same way.

6. The normally closed (N.C.) input terminals not to be used at the motion control unit I/O connec-

tor section must be short-circuited at the connector.

7. Make the setting so that the servo can be turned ON/OFF by the /S-ON signal.

CN1

3

4

5

16

13

12

11

19

15

14

18

1

5
6

1

19
20

L1C

L3

L2

L1

L2C

35

34

20

36

47
32

MC unit manufactured
by OMRON

DRV connector

SGDH SERVOPACK

(CV500-MC221 / MC421)

(CS1W-MC221 / MC421)

C200H-MC221

10

10

17

2

4
6

14

1

2

31

33

44

40

ALM+

/S-ON

/ALM-RST

SG

SG

ALM-

FG

PAO

/PAO

/PBO

PBO

PCO

/PCO

V-REF

+24V-IN

24V input

24VDC

24VDC

24V input ground
X-axis alarm input

X-axis alarm reset output

X-axis run reference output

X-axis feedback ground

X-axis phase-A input

X-axis phase-/A input

X-axis phase-B input

X-axis phase-/B input

X-axis phase-Z input

X-axis phase-/Z input

X-axis speed reference

Axis speed reference ground

24V output

24V output ground

I/O connector

24V input

X-axis CW limit input

X-axis CCW limit input

X-axis immediate stop input
X-axis origin proximity input

24V input ground

Shell

Control power supply

Main circuit power supply

CN2

W

V

U

Linear servomotor

Linear scale

Properly treat the ends of shielded wired.

M

PG

Serial

converter

unit