Warning, 4) dc power supply input – Yaskawa SGDH Linear Sigma Series User Manual

Page 185

Advertising
background image

7.2 Wiring Main Circuit

7-21

7

(4) DC Power Supply Input

When using the main circuit power supply input of the SGDH SERVOPACK with DC power supply, use the fol-
lowing power supply and set the parameter Pn001.2 to 1. Also, read carefully to the following ‘Important’ sec-
tion.

1. Servomotor returns the regenerative energy to the power supply when regenerating. SERVOPACK does

not regenerate with DC power supply input specifications, so regenerate the energy on the power supply
side.

2. Take appropriate measures to ensure that a high charging current stays inside the SERVOPACK when

power is OFF.

(a) Main Circuit and Control Power Supply Input

The following shows the connection for the main power supply and the control power supply.

(b) Setting Parameters

• SGDH SERVOPACK is applicable for both AC and DC power supply input excluding 7.5-kW control power

supply input.
However, if the DC power supply input supplies a voltage without setting ‘1’ (for DC power supply input) in
the parameter Pn001.2, the SERVOPACK’s internal elements will burn and may cause fire or malfunction.
When using the SERVOPACK with DC power supply input, confirm the following setting of parameters.

WARNING

IMPORTANT

Terminal

Symbol

Name

Main Circuit Power

Supply Voltage

when AC Power

Supply input

Functions

1 or

Main circuit plus terminal

200 VAC
(SGDH-††AE)

270 to 310 VDC

400 VAC
(SGDH-††DE)

513 to 648 VDC

Main circuit minus terminal

Common to all models

0 V

L1C, L2C

Control power supply input
terminal

200 VAC
(SGDH-††AE)

Single-phase 200 to 230 VAC +10%, -15% (50/
60Hz) or 270 to 310 VDC, without polarity,
excluding 7.5-kW control power supply input.

24V, 0V

400 VAC
(SGDH-††DE)

24 VDC (

±

15%)

Parameter

Meaning

Pn001

n.†0††

Not applicable for main circuit DC power supply input: Input the AC power sup-
ply for the terminal L1, L2 or L3.

n.†1††

Applicable for main circuit DC power supply input: Input the DC power supply
between the terminal

and the terminal

1, or the terminal

and the termi-

nal .

• When changing the parameters, turn the power ON again for the necessity of the effective setting.

Advertising