background image

3 Specifications and Dimensional Drawings

3.6.2 SGLG†-40 Linear Servomotors

3-20

(2) Standard-force Magnetic Way: SGLGM-40†††C / SGLGM-40†††CT

22.5

(0.89)*

* Reference length

Units: mm (in)

L2

L2

X

X

9

±0.2

(0.35

±0.01

)

7.4

±0.2

(0.29

±0.01

)

X-X

4-C1

13 (0.51)*

4-C1

X-X

X

X

SGLGM-
40†††C

c

SGLGM-
40†††CT

d

7 (0.28)

Pitch 45 (1.77)

Nameplate

Warning label

22.5

(0.89)

N

×φ5.5 (φ0.22) mounting hole (per unit)

22.5

(0.89)

Pitch 45 (1.77)

N

×M5 mounting screws, depth 13 (0.51) (per unit)

(

d

Only for SGLGM-

CT.)

-0.1

-0.3

L1

(1 unit)

22.5

(0.89)*

12.7

(0.50)

25.4
(1.0)

25.4
(1.0)

62 (2.44)

62 (2.44)

φ10 (

φ0.39)

φ5.5 (

φ0.22)

φ10 (

φ0.39)

φ5.5 (

φ0.22)

5.4

(0.21)

5.4

(0.21)

7.4

±0.2

(0.29

±0.01

)

9

±0.2

(0.35

±0.01

)

Standard-force Magnetic Way

Model SGLGM-

L1

L2

N

Approx.

Mass

kg (lb)

Standard

Force

40090C or 40090CT

90

(3.54)

45

(1.77)

2

(0.08)

0.8

(1.76)

40225C or 40225CT

225

(8.86)

180

(7.09)

5

(0.20)

2.0

(4.41)

40360C or 40360CT

360

(14.17)

315

(12.40)

8

(0.31)

3.1

(6.83)

40405C or 40405CT

405

(15.94)

360

(14.17)

9

(0.35)

3.5

(7.72)

40450C or 40450CT

450

(17.72)

405

(15.94)

10

(0.39)

3.9

(8.60)

Advertising