Yaskawa SGDH Linear Sigma Series User Manual

Page 357

Advertising
background image

11.1 Troubleshooting

11-5

11

11.1.3 Alarm Display Table when the Application Module is Used

The following special alarms will occur when the SGDH SERVOPACK and an application module are used
together. The relation between alarm displays and alarm code outputs is shown in Table 11.3.

Note: 1. The following types of application modules are available:

NS100 (JUSP-NS100): MECHATROLINK-I application module
NS115 (JUSP-NS115): MECHATROLINK-II application module
NS300 (JUSP-NS300): Device Net application module
NS500 (JUSP-NS500): PROFIBUS-DP application module
NS600 (JUSP-NS600): INDEXER application module

2. For troubleshooting application module alarms, refer to relevant application module manual.

Manual numbers are described in Related Manuals on page v.

3. When mounting the NS115 module, observe the following restrictions on use. If the NS115 mod-

ule is connected to the hand-held digital operator or communications are being sent to or from
SigmaWin+ and another device (a personal computer) during execution of the following
MECHATROLINK-II commands, an A.ED alarm (Command execution incomplete) occurs and
the commands are not successfully sent.

PRM_RD, PRM_WR, PPRM_WR, CONFIG, ALM_RD, ALM_CLR,
SENS_ON, ADJ, ID_RD

Table 11.3 Alarm Displays and Outputs when the SERVOPACK and an Application Module Is Used Together

Alarm

Display

Application Module

which Detects Alarms

Alarm Name

Meaning

Alarm Code

Output

Servo
Alarm

(ALM)

Output

NS

100

NS

115

NS

300

NS

500

NS

600

ALO1 ALO2 ALO3

A.E0

{

{

{

{

{

No Application Module

No application module installed.

H

L

L

H

A.E1

{

{

{

{

{

Application Module Time-
out

No response from the application
module.

A.E2

{

{

{

{

{

Watchdog Counter Error of
Application Module

WDC error in the application
module

A.E4

{

MECHATROLINK-II
Transmission Cycle
Setting Error

Transmission cycle setting of
MECHATROLINK-II is incor-
rect.

A.E5

{

{

Watchdog Timer Error

MECHATROLINK-I/II synchro-
nization error

A.E6

{

{

{

NS100/115 Communica-
tions Error

MECHATROLINK-I/II commu-
nications error

NS300 Duplicate MAC ID
Error

Same node address already exists
on the DeviceNet network.

A.E7

{

{

{

{

{

Application Module
Detection Error

No application module was
detected.

A.E9

{

BUS-OFF Error

Fatal communications error has
occurred in DeviceNet communi-
cations.

A.EA

{

{

{

{

SERVOPACK Malfunc-
tion

SERVOPACK is defective.

A.EB

{

{

{

{

SERVOPACK Initial
Access Error

Initial processing failed.

A.EC

{

{

{

{

SERVOPACK WDC Error

SERVOPACK WDC error

A.ED

{

{

{

{

Command Execution
Incomplete

Command was interrupted.

A.EF

{

Application Module Error

Some kind of alarm occurred in
the NS600.

Advertising