4 cables for connecting hall sensors, 4 cables for connecting hall sensors -9 – Yaskawa SGDH Linear Sigma Series User Manual
Page 137
Advertising

6.4 Cables for Connecting Hall Sensors
6-9
6
6.4 Cables for Connecting Hall Sensors
(1) Cable Type
(2) Dimensional Drawing
(3) Specifications
Type
Length (L)
JZSP-CLL10-01
1 m (3.28 ft)
JZSP-CLL10-03
3 m (9.84 ft)
JZSP-CLL10-05
5 m (16.40 ft)
JZSP-CLL10-10
10 m (32.81 ft)
JZSP-CLL10-15
15 m (49.21 ft)
Serial converter unit end
Hall sensor end
1
5
6
9
1
5
6
9
Connector type:17JE-23090-02
(D8C) (9-pin, soldered)
made by DDK Ltd.
Connector type: 17JE-13090-02(D8C)
(With stad) (9-pin, soldered)
made by DDK Ltd.
Finished diameter
φ6.8 (φ0.27)
Cable
(AWG22
×2+AWG24×4)
Units: mm (in)
Signal
Pin No.
1
2
3
4
5
7
8
9
6
+5V
Phase U input
Phase V input
Phase W input
0V
−
−
−
−
−
−
−
−
+5V
Phase U input
Phase V input
Phase W input
0V
Hall sensor end
Signal
Pin No.
1
2
3
4
5
7
8
9
Case
6
Shield
Case
Shield
Serial converter unit end
Advertising