1 Outline

1.3.3 Three-phase, 400 V Main Circuit

1-10

1.3.3 Three-phase, 400 V Main Circuit

Digital

operator

Personal computer

(Refer to 2.6.1.)

Regenerative
resistor

Noise filter

Molded-case
circuit breaker
(MCCB)

Magnetic
contactor

Host controller

I/O signal cable

SGDH-††DE
SERVOPACK

Power supply
Three-phase 400 VAC

R S T

Protects the power
supply line by shutting
the circuit OFF when
an overcurrent is
detected.

Eliminates external
noise from the power
line.

Connect an external
regenerative resistor
to terminals B1 and B2
if the rgenerative capacity
is insufficient.

Turns the servo
ON and OFF.
Install a surge
suppressor.

(Refer to 2.6.1.)

(Refer to 2.6.1.)

(Refer to 2.6.4.)

Refer to

2.6.3.)

(Refer to 2.6.3.)

(Refer to 2.6.2.)

Connection cable
for digital operator

Connection cable
for personal computer

L1

L2

L3

U

V

W

24V
0V
B1
B2
B3

1

2

C

N
3

C
N
1

C
N
2

MODE/SET

DATA/

CHARGE

POWER

YASKAWA

SERVOPACK

SGDH-

200V

+

DC power
supply
(24 VDC)

*1

*3

*2

(Refer to 2.6.5.)

Linear servomotor
wirh core

Linear scale
(To be provided by
users.)

Connection cable
for hall sensor

Encoder
cable

Main circuit cable for
linear servomotor

Serial convertr unit

Connection cable for
serial convertr unit

(Refer to 2.5.)

(Refer to 2.5.)

(Refer to 2.5.)

(Refer to 2.5.)

(Refer to 2.4.)

*3: To connect a DC reactor, refer to 7.5.5 DC Reactor for Harmonic
Suppression.

*1: Use a 24 VDC power supply (To be provided by users).

*2: Before connecting an external regenerative resistor to
the SERVOPACK, be sure to disconnect the lead between terminals
B2 and B3.