7 Wiring

7.4.6 Interface Circuit

7-30

(2) Sequence Input Circuit Interface

CN1 connector terminals 40 to 47 is explained below.
The sequence input circuit interface connects through a relay or open-collector transistor circuit. Select a low-
current relay otherwise a faulty contact will result.

Note: The 24 VDC external power supply capacity must be 50 mA minimum.

(3) Sink Circuit and Source Circuit

The SERVOPACK’s I/O circuit uses a bidirectional photocoupler. Select either the sink circuit or the source cir-
cuit according to the specifications required for each machine.

(4) Output Circuit Interface

There are three types of SERVOPACK output circuits:

(a) Line-driver Output Circuit

CN1 connector terminals, 33-34: phase-A signal, 35-36: phase-B signal and 19-20: phase-C signal are
explained below.
Encoder serial data converted to two-phase (phases A and B) pulse output signals (PAO, /PAO, PBO, /PBO)
and zero-point pulse signals (PCO, /PCO) are output via line-driver output circuits. Normally, the SERVO-
PACK uses this output circuit in speed control to comprise the position control system at the host controller.
Connect the line-driver output circuit through a line receiver circuit at the host controller.

Relay Circuit Example

Open-collector Circuit Example

3.3 k

Ω

/S-ON, etc.

SERVOPACK

24 VDC

+24VIN

+24VIN 3.3 kΩ

/S-ON, etc.

SERVOPACK

24 VDC

Sink Circuit

Source Circuit

24 V

I/O power

supply

SERVOPACK input

+

SERVOPACK input

+

24 V

I/O power

supply

Advertising