3 basic mode selection and operation, 3 basic mode selection and operation -4, 1) using the digital operator – Yaskawa SGDH Linear Sigma Series User Manual

Page 212

Advertising
background image

8 Digital Operator/Panel Operator

8.1.3 Basic Mode Selection and Operation

8-4

8.1.3 Basic Mode Selection and Operation

The basic modes include: Status display mode, Utility Function Mode, Parameter Setting Mode, and Monitor
Mode.
Select a basic mode to display the operation status, set parameters and operation references.
The basic mode is selected in the following order.

(1) Using the Digital Operator

Turn ON the power

Fn†††: Utility Function Mode
(Refer to 8.2)

Pn†††: Monitor Mode
(Refer to 8.4)

Press DSPL/SET Key.
A basic mode is selected in the following order.

Repeat

DATA

ENTER

DSPL

SET

Press DSPL/SET Key and UP or DOWN Key to select the desired parameter number.
Then, press DATA/ENTER Key to display the contents of selected parameter number
in the selected mode. (Refer to each operation instruction described later.)

Status Display Mode (Refer to 8.1.4.)

Press .

Press .

DSPL

SET

Press .

DATA

ENTER

Press .

Pn†††: Parameter Setting Mode
(Refer to 8.3)

DSPL

SET

Press .

DSPL

SET

Press .

DATA

ENTER

Press .