Yaskawa SGDH Linear Sigma Series User Manual

Page 230

Advertising
background image

8 Digital Operator/Panel Operator

8.3.1 Setting Parameters

8-22

(2) Function Selection Parameters

(a) Types of Function Selection Parameters

Refer to 12.4.2 List of Parameters.

If the parameters with “After restart” in “Setting Validation” column in the table are changed, turn OFF the
main circuit and control power supply and ON again to validate new setting.

• Pn10B.1 and Pn110.0 require the power to be reset as mentioned above.
• Pn10B.0, Pn110.1, and Pn110.2 are enabled with the off-line, so the power does not have to be reset.

Category

Parameter

No.

Name

Factory

Setting

Setting

Validation

Function Selection
Parameter

Pn000

Function Selection Basic Switch

0000

After restart

Pn001

Function Selection Application Switch 1

0000

After restart

Pn002

Function Selection Application Switch 2

0000

After restart

Pn003

Function Selection Application Switch 3

0002

Immediately

Pn080

Function Selection Application Switch 80

0000

After restart

Servo Gain Related
Parameter

Pn10B

Gain Application Switches

0000

After restart/

Immediately

Pn110

Online Autotuning Switches

0010

After restart/

Immediately

Position Control Related
Parameter

Pn200

Position Control References Selection Switches

0000

After restart

Pn207

Position Control Function Switches

0000

After restart

Pn218

Reference Pulse Multiplication Function
Selection
(For the software version 32 or later)

0000

After restart

Force Control Related Pa-
rameter

Pn408

Force Function Switches

0000

Immediately

Sequence Related
Parameter
(Input Signal Selection)

Pn50A

Input Signal Selection 1

2100

After restart

Pn50B

Input Signal Selection 2

6543

After restart

Pn50C

Input Signal Selection 3

8888

After restart

Pn50D

Input Signal Selection 4

8888

After restart

Pn513

Input Signal Selection 5
(For the software version 32 or later)

0088

After restart

Sequence Related
Parameter
(Output Signal Selection)

Pn50E

Output Signal Selection 1

3211

After restart

Pn50F

Output Signal Selection 2

0000

After restart

Pn510

Output Signal Selection 3

0000

After restart

Pn512

Output Signal Reversal Setting

0000

After restart

IMPORTANT

Advertising