1) related parameters – Yaskawa SGDH Linear Sigma Series User Manual

Page 316

Advertising
background image

9 Operation

9.11.4 Force Limiting Using an External Force Limit and Analog Voltage Reference

9-72

9.11.4 Force Limiting Using an External Force Limit and Analog Voltage Reference

This function can be used to combine force limiting by an external input signal and by analog voltage reference.
Because the force limit by analog voltage reference is input from T-REF (CN1-9, 10), this function cannot be
used during force control. Use /P-CL (CN1-45) or /N-CL (CN1-46) for force limiting by external input signal.

When /P-CL (or /N-CL) is ON, either the force limit by analog voltage reference or the setting in Pn404 (or
Pn405) will be applied as the force limit, whichever is smaller.

(1) Related Parameters

* The setting unit is a percentage of rated force (i.e., the rated force is 100%).

Force limit
value

Speed
reference

Pn300

+
+

+

-

Pn400

T-REF

V-REF

Pn404

( /P-CL:ON )

Forward torque
limit value (Pn483)

Pn405

( /N-CL : ON)

(Pn100)

Speed loop

integral

time

constant
(Pn101)

Speed loop
gain

Speed feedback

Force
reference

Reverse torque
limit value (

Pn484)

/N-CL

/P-CL

SERVOPACK

Parameter

Meaning

Pn002

n.†††3

Speed control option: When /P-CL or /N-CL is enabled, the T-REF terminal is used as the
external torque limit input.

When n.†††2 is set, T-REF is used for force feed-forward input, but the functions cannot be used together.

Pn404

Forward External Force Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

%

100

Immediately

Pn405

Reverse External Force Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

%

100

Immediately