7.4 Examples of I/O Signal Connections

7-23

7

7.4 Examples of I/O Signal Connections

7.4.1 Speed Control Mode

* 1.

represents twisted-pair wires.

* 2. The time constant for the primary filter is 47

μs.

* 3. Enabled by the parameter setting.
* 4. Customers must purchase a 24 VDC power supply with double-shielded enclosure.
Note: The functions allocated to the input signals SI0 to SI6 and the output signals SO1 to SO3 can be

changed by using the parameters. Refer to 8.3.2 Input Circuit Signal Allocation and 8.3.3 Output
Circuit Signal Allocation
.

SERVOPACK

PBO

PCO

/PBO

PAO
/PAO

/PCO

/V-CMP+

/V-CMP-

/TGON+

/TGON-

/S-RDY+

ALM+

ALM-

FG

10

27

28

29

30

31

32

25

(SO1)

(SI0)

(SI1)

(SI2)

(SI3)

(SI4)

(SI5)

(SI6)

(SO2)

(SO3)

26

19

33
34

35
36

20

+24 V

+24VIN

3.3 k

Ω

/S-ON

/P-CON

P-OT

N-OT

/ALM-RST

/N-CL

47

41

43

42

44

45

/P-CL

46

40

/S-RDY-

∗4.

V-REF

SG

A / D

5

6

∗2.

∗1.

LPF

T-REF

SG

1

SG

9

∗2.

LPF

ALO1

ALO2

ALO3

37

38

39

Servo ON

(Servo ON when ON)

Reverse run prohibited

(Prohibited when OFF)

Forward run prohibited

(Prohibited when OFF)

Alarm reset

(Reset when ON)

Reverse current limit

(Limit when ON)

Forward current limit

(Limit when ON)

P control

(P control when ON)

Speed reference

(

±

2 to

±

10V

/rated motor

speed)

External force
limit/Force feed
forward
(

±

1 to

±

10 V

/rated force)

∗3.

Connect shield to

connector shell.

Connector

shell

PG dividing ratio output

Applicable line receiver

SN75175 manufactured

by Texas Instruments or

the equivalent corresponding

to MC3486

Running output

(ON when the motor speed

exceeds the settings.)

Servo ready output

(ON when ready)

Servo alarm output

(OFF for an alarm)

Photocoupler output

Max. operating voltage:
30 VDC

Max. operating current:
50 mA DC

Speed coincidence detection

(ON when speed coincides.)

Alarm code output

Max. operating voltage:
30 VDC

Max. operating current:
20 mA DC

Advertising